Volume Of Solid Of Revolution Calculator Y-Axis . In the input field, enter the required values or functions. The volume of the solid formed by revolving the region about the axis is. The volume of a solid of revolution (xaxis) MathsLinks from mathslinks.net ∫ 0 2 π y 2 d y + ∫ 2 4 π ( 4 − y) 2 d y = 8 π 3 + 8 π 3 = 16 π 3. In the above example the object was a solid. If you are using disk method, it should be two integrals:

Transformer Fault Current Calculation


Transformer Fault Current Calculation. Can be found on the nameplate. The full load current i (a) in amps is equal to 1000 times of transformer rating s (kva) in kva divided by the multiplication of root 3 times of line to line voltage v (v) in volts.

Transformer Available Fault Current
Transformer Available Fault Current from www.invbat.com

Welcome to schneider electric's fault current calculator. So if the primary side of your transformer faults, the fault current must go back to its source in order to clear the fault, no matter where on the planet that source is located. The fault current at the downstream switchboard may be slightly less depending on the impedance of the cables/buses.

The Full Load Current I (A) In Amps Is Equal To 1000 Times Of Transformer Rating S (Kva) In Kva Divided By The Multiplication Of Root 3 Times Of Line To Line Voltage V (V) In Volts.


The fault current at the downstream switchboard may be slightly less depending on the impedance of the cables/buses. Single phase with cable run. X/r ratio at the utility transformer.

This Video Describes How To Calculate The Fault Current Using A Transformers Rated Percent Impedance.


I (a) = s (kva) *1000 / (1.732 * v (v)) if you take the phase to neutral. Can be found on the nameplate. I p r i m a r y = p k v a 3 v p r i m a r y.

By Steven Mcfadyen On July 1St, 2012.


A fault current calculation determines the maximum available current that will be available at a given node, or location, in the system. Use a clamp on ammeter to measure the primary current if the load is connected to the secondary is known & the secondary voltage is known or can be measured & the prim to sec ratio of transformer is known. Now we are at more like 40ka.

I Hope I Have Stated My Question Clearly.


Available fault current at utility transformer secondary: System modifications can result in higher fault currents. Earth fault loop impedance zs = voltage to earth uo fault current ia = voltage to earth uo fault current ia loop impedance zs actual secondary fault.

In A Common Household Or Industrial Electrical System, We Are Not Allowed To Use The Earth/Soil As A Fault Current Path (With The Exception Of Tt Systems, Where We Can.


I s e c o n d a r y = p k v a 3 v s e c o n d a r y. To calculate the actual fault current in a transformer we can refer to the below formula taken from bs7671:2008, 411.4.5 and use the above figure for the transformers total impedance (zsec). These figures are based on change in